1、Cut off power.
2、Take off the original transformer.
3、Connect input line (red line) of 4827 with LOAD1/LOAD2 and nature of dim switch.(such as: PLCBUS-R 2220E),connect output line(white line) with Halogen LV Lamp.
4、Make sure that no brass wires are renegade or exposed, wrap the interfaces with insulating tape.
5、Fix 4827 in right place.
6、Turn on power.
Notice: 1、The
rated voltage of this module is AC220V. 2、This
module can only connect with the load which wattage is lower than
the max. 3、Make
sure the power has been cut off before installation. 4、The
ventilation of the place where to install the transformer should be
good and the distance between Transformer and the lamp should be
longer than 150mm; 5、The
temperature should be lower than 50 ̊C. 6、Parallel
connected two or more than two transformers is not allowed.